MCOMMWLCDis
GSMbased Starter with automatic water level controller,automatic water-level
controller for overhead tanks that switches on/off the pump motor when water in
the tank goes below/above.the device works for 2 Phase/ 3Phase up to 80 Hp.it
can be connect to any type of Starter. Eg. DOL and Star delta etc. Through MCOMMWLCDcan operate Pump from
anywhereor Local or WLCD(overhead tanks level demand).
Features
·
built-in 32-bit ARM Micro controller
·
built-in Watchdog
·
built-inwater level
controller
·
Current Range / HP: 3 – 99 Amps/1-80 Hp
·
built-in seven segment
display: Digital
Voltmeter 180 – 520 V and Digital Ammeter 3 – 99 Amp, GSM Network availability
in Percentage.
·
Push
button for Auto and Manual selection
·
Three
Mode operations: -Auto (online),WLCD (overhead tanks level
demand), Manual (local)
Manual Mode: - Users can operate
pump through local ON/OFF push button with Protections.
WLCD Mode: -Here is a simple,
automatic water-level controller for overhead tanks that switches on/off the
pump motor when water in the tank goes below/above the minimum/maximum level.
The water level is sensed by two floats to operate the switches for controlling
the pump motor.
Auto Mode:Users can operate
pump through Mobile (SMS/Call/Web and Mobile App)
·
Start
/ Stop / Monitor / Set your motor from any phone
·
Real
time IoT based data monitoring web and mobile app for pump status.
·
Talks
Online in Local Language
·
Four
Authorized users can be added
·
SMS
and online Realtime reports
·
Online
Parameter Settings by SMS and web /mobile App.
·
Call
Auto Lift and Auto Cut
·
Hour
Meter, Total Hour
·
MeterSite
Settable Four Digit Password with SIM Tracking
·
Missed
Call/SMSand web & Mobile app based ON / OFF pump operation.
·
Web
Based Android Application
·
Receive
Phone Call for Fault & Power Return (Call Back)
·
Select
Auto / Manual Mode by SMS, Web & Mobile app.
·
Real
timeVerbal Voltage & Current Information on web and Mobile APP.
·
Multi
Location with Fault and SMS Log in web /Android App.
·
IOT
Based Web Data Logging on Server
Protections:
·
Phase
Failure (Supply Side)
·
Phase
Failure (Motor Side)
·
Reverse
Phase (Supply Side)
·
Voltage
and Current Unbalance
·
Electronic
Overload (Site Settable)
·
Remote
Sensing Dryrun (Site Settable)
·
High
/ Low Voltage (Site Settable)
·
Extreme
High Current (Fixed at 50Amps.)
Timers:
·
Power
ON Timer for Auto Start (Site Settable)
·
Star
Delta Timer (Site Settable)
·
Dry
run Auto Start Timer OFF – 5 – 720 mins. (Site Settable)
·
Clock
Based 4 ON & 4 OFF Timers (MTC)
·
Motor
OFF Timer OFF – 5 – 720 mins. (Site Settable)
·
Repeat
Run Timer OFF – 5 – 999 mins. (Site Settable)
·
Time
Compensation Enable / Disable Facility
Specifications
1. System Settings
• Input Voltage (AC) : 250 – 470 VAC, 50 Hz
• On voltage (Cold Start): 250
VAC
• Auto Off voltage: 200 VAC
2.
Protections / Setting Parameters
Pump Current Range : 3 – 99 Amp
2.
Protections / Setting Parameters
Parameter |
Setting
Range |
Default
setting |
Trip
Time Delay |
Display |
LED |
Phase
Failure |
Fixed |
Fixed |
4
sec ± 1 sec |
SPP |
YES |
Reverse
Phase |
Fixed |
Fixed |
4
sec ± 1 sec |
SPP |
YES |
Voltage
Unbalance |
Fixed |
Fixed |
4
sec ± 1 sec |
SPP |
YES |
Current
Unbalance |
20%
– 70% |
50% |
4
sec ± 1 sec |
CUB |
YES |
Overload |
20%
– 60% |
>
140 % |
15
sec |
OL |
YES |
Dry
run |
60%
– 95% |
<
75 % |
15
sec |
DRN |
YES |
High
voltage |
450
– 500 V |
480
V ± 2 V |
Fixed |
HIU |
YES |
Low
voltage |
180
– 350 V |
250
V ± 2 V |
Fixed |
LOU |
YES |
Extremely
High Current |
Fixed |
50
Amps. |
3
sec |
EHC |
NO |
3.TimersSetting
Parameter |
Setting Range |
Default setting |
Display |
LED |
Power on Timer |
3 sec – 300 sec |
60 sec ± 3 sec |
PONT |
YES |
Star Delta Timer |
3 sec – 300 sec |
10 sec ± 2 sec |
OFF |
YES |
Motor ON Timer |
5 – 720 min |
OFF |
OFF |
YES |
Repeat Run Timer |
5 – 999 min |
OFF |
RRT |
YES |
Dryrun Auto Start Timer |
5 – 720 min |
OFF |
DRAT |
YES |
Clock Based 4 MTC Timer |
As per 24 Hours |
OFF |
OFF |
YES |
Cyclic Timer |
Clock 24 Hours |
OFF |
CYC |
YES |
4.
Monitoring Display
• Digital
Voltmeter : 180 – 520 V
• Digital
Ammeter : 3 – 99 Amp
5.Monitoring
Web and Mobile app:
·
Real
time monitoring for all parameters.
6.
Reset
• Resetting mode : Manual by OFF switch, SMS, WEB, Mobile
app.
7.
Output Relay Contact
• Relay
Mechanical life : 10 lac
operations
• Dielectric
Strength : 2.2 KV , 50 Hz for 1 min
8.
Enclosure & Mounting
• Enclosure
Material : MS powder coated Enclosure
• Mounting : Wall Mounting with 4 screw M4 × 15 mm
• Temperature : 5 to 60°C
• Humidity : Up to 90% RH
9.
Dimensions & Weight
• L × W × D (mm) : 250 x 160 x 74mm
• Power Consumption : Less than 4 Watts
• Weights : 990 gms.
Applications
Industrial
Agriculture
Irrigation
Domestic
Connection
Diagram
INPUT 415 VOLT |
PUMP START |
PUMP STOP |
CT CONECTION (R Y B) |
LEVEL SENSOR |
THREE WIRE FOR THREE PHASE SUPPLY, RED FOR R
PHASE, YELLOW FOR Y PHASE, BLUE FOR B PHASE. |
TWO GREEN WIRE |
TWO BLACK WIRE |
TWO WIRE FOR R PHASE (Red and black), TWO WIRE FOR
Y PHASE (Yellow and black), TWO WIRE FOR B PHASE (Blue and black). |
TWO-TWOWHITEWIRE FOR LOWER AND UPPER LEVEL |